This is the preview version of the Wisconsin State Legislature site.
Please see http://docs.legis.wisconsin.gov for the production version.
NR 439.07(2)(e)(e) A description of the number and location of the sampling ports and sampling points including a diagram showing the distance of the sampling ports from the nearest upstream and downstream flow disturbances and the stack dimensions for each measurement location.
NR 439.07(2)(f)(f) A statement indicating the production rate and the operating conditions at which the test will be conducted.
NR 439.07(2)(g)(g) Facility name, physical address, city, state, and zip code.
NR 439.07(2)(h)(h) Facility contact name and phone number.
NR 439.07(2)(i)(i) Facility identification number and active permit numbers.
NR 439.07(2)(j)(j) Stack numbers, emissions unit numbers, and control device numbers.
NR 439.07(2)(k)(k) Pollutant emission limitations.
NR 439.07(2)(L)(L) List of the applicable rules, orders, and permit conditions requiring the test.
NR 439.07(2)(m)(m) Test firm name, address, city, state, and zip code.
NR 439.07(2)(n)(n) Test firm contact name and phone number.
NR 439.07(3)(3)Test plan evaluation. In evaluating the test plan, the department shall respond to the source owner or operator within 14 calendar days of receipt of the plan if amendments are needed. If the department does not respond within 14 calendar days, the test may proceed as described in the test plan. The department may require any of the following:
NR 439.07(3)(a)(a) A pre-test conference which includes the owner or operator of the source, the tester and the department to discuss any deficiencies in the plan or settle any test procedure questions the department, the tester or the source owner or operator might have.
NR 439.07(3)(b)(b) Any reasonable stack or duct modification or any change to the sampling method that is deemed necessary by the department to obtain a representative sample.
NR 439.07(3)(c)(c) Additional tests for the same pollutants to be performed at the same or different operating conditions.
NR 439.07(3)(d)(d) A rescheduling of the test to accommodate witnessing or source production schedules.
NR 439.07(4)(4)Notification of test plan revision. The owner, operator, or designee of a source shall notify the department of any modifications to the test plan at least 7 calendar days prior to the test. In the event the owner or operator is unable to conduct the compliance emission test on the date specified in the test plan, due to unforeseeable circumstances beyond the owner or operator's control, the owner or operator of a source shall notify the department at least 7 calendar days prior to the scheduled compliance emission test date and specify the date when the test is rescheduled or arrange a rescheduled date with the department.
NR 439.07(5)(5)Testing facilities. The department may require the owner or operator of a source to provide the following emission testing facilities:
NR 439.07(5)(a)(a) The installation of sampling ports and safe sampling platforms meeting the requirements of EPA Method 1.
NR 439.07(5)(b)(b) A safe work area for the test crew or any witnessing personnel.
NR 439.07(5)(c)(c) Safe access to the work area or sampling platform.
NR 439.07(5)(d)(d) Utilities for the sampling equipment.
NR 439.07(5)(e)(e) Instrumentation to monitor and record emissions data.
NR 439.07(6)(6)Witnessing requirements. The department may require that a department representative be present at any compliance emission test. The department representative has the following authority:
NR 439.07(6)(a)(a) The department representative shall, during the test, supply the tester with the appropriate audit samples required in the reference method for quality assurance purposes.
NR 439.07(6)(b)(b) The department representative may require the tester to provide the department a copy of all test data and equipment calibration data prepared or collected for the test.
NR 439.07(6)(c)(c) The department representative may take any or all of the test samples collected during the test for analysis by the department.
NR 439.07(6)(d)(d) The department witness may require the source owner or operator and tester to correct any deficiency in the performance of the test provided that the department witness notifies the source owner or operator and tester of the deficiency as soon as it is discovered. The failure of a source owner or operator and tester to correct any deficiency may result in the department refusing to accept the testing results.
NR 439.07(7)(7)Emission testing equipment calibration requirements. The following components of any emission sampling train or associated sampling equipment shall be calibrated not more than 60 calendar days before the test:
NR 439.07(7)(a)(a) Any equipment used to measure gas velocity.
NR 439.07(7)(b)(b) Any equipment used to meter sample gas volume.
NR 439.07(7)(c)(c) Any equipment used to regulate sample gas flow.
NR 439.07(7)(d)(d) Any equipment used to measure temperature.
NR 439.07(7)(e)(e) Any gas sampling nozzle used during the emission test.
NR 439.07(7)(f)(f) Any equipment used to determine gas molecular weight.
NR 439.07(7)(g)(g) Any other sampling equipment that requires periodic calibration.
NR 439.07(8)(8)Procedures for conducting compliance emission tests. In conducting any compliance emission test the following procedures apply:
NR 439.07(8)(a)(a) General provisions. Except as provided for in par. (c), (d), (f) or (g), an emission test shall consist of a minimum of 3 representative repetitions, as determined by the department, of the applicable test method with a minimum sampling time of one hour per repetition. Shorter sampling times as referenced in par. (g) may be used with the written approval of the department. The arithmetic mean of the results of all repetitions shall be used to determine compliance with an emission limitation. In addition, the following requirements apply:
NR 439.07(8)(a)1.1. The gas flow rate, in dry standard cubic feet per minute, shall be determined during each repetition of an emission test using Method 1, 1A, 2, 2A, 2B, 2C, 2D, 2E, 2F, 2G, 2H, 3, 3A, 3B, 3C, and 4 in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13), as applicable.
NR 439.07(8)(a)2.2. A record shall be maintained of all persons who have handled the test samples.
NR 439.07(8)(b)(b) Particulate matter. When compliance with a particulate matter emission limitation is determined using Method 5, 5A, 5B, 5D, 5E, 5F, 5G, 5H, 5I, or 17 in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13), the test shall consist of 3 representative repetitions. In addition, all of the following provisions apply:
NR 439.07(8)(b)1.1. Sootblowing shall be performed during one repetition of each test for particulate matter emissions on any boiler that routinely employs sootblowing, unless the boiler uses a continuous sootblowing system. If a continuous sootblowing system is operating during the test, compliance with the emission limitation shall be determined by the arithmetic mean of the results of all repetitions. If a continuous sootblowing system is not operating during the test, the representative average pounds of particulate matter emissions per million Btu heat input shall be determined by the following equation:
E = Es ((A + B) S/AR) + Ens((R - S)/R - (BS/AR))
where:
E is the weighted average pounds of particulate matter per million Btu heat input
Es is the pounds of particulate matter per million Btu heat input for test runs during sootblowing
Ens is the arithmetic average pounds of particulate matter per million Btu heat input for test runs with no sootblowing
A is the hours of sootblowing during test runs containing sootblowing
B is the hours with no sootblowing during test runs containing sootblowing
R is the average hours of boiler operation per 24 hours
S is the average hours of sootblowing per 24 hours
NR 439.07(8)(b)2.2. Each repetition for a particulate matter emissions test shall have a sample volume of at least 30 dry standard cubic feet.
NR 439.07(8)(b)3.3. Method 17, for particulate matter emissions, in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13), may not be used where stack or duct temperatures exceed 320°F.
NR 439.07(8)(b)4.4. Heat input shall be equal to the fuel use rate multiplied by the heat content of the fuel on an as-fired basis. Fuels shall be analyzed for heat content using the procedures in Method 19 in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13). Alternately, heat input may be determined using a continuous emission monitor that meets the applicable performance specifications in 40 CFR part 60, Appendices B and F, or, for affected sources, the performance specifications in 40 CFR part 75, Appendices A to I, incorporated by reference under s. NR 484.04 (21), (21m), and (27).
NR 439.07(8)(b)5.5. Any boiler emission rate in pounds per million Btu heat input shall be determined using the heat input based on fuel use rate. The emission rate may be determined using the F-Factor calculation shown in Method 19 in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13). If the F-Factor method is used, an ultimate fuel analysis shall be performed. An integrated gas sample, using Method 3, 3A, 3B, or 3C in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13), shall be collected and analyzed for oxygen and carbon dioxide content. Other methods for determining the boiler heat input may be used only if approved, in writing, by the department.
NR 439.07(8)(b)6.6. If cyclonic flow is a possibility at a particulate matter emission test location, a test for the presence of cyclonic flow shall be performed before the particulate matter test using the procedures in Method 1 in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13). If cyclonic flow is present, the flow must be straightened before testing can begin unless the source owner or operator demonstrates, to the department's satisfaction, the acceptability of the location using the alternate procedure to Method 1. If cyclonic flow is not present, testing can proceed.
NR 439.07(8)(b)7.7. Except for sources subject to emission testing requirements under 40 CFR part 60, the department may require the owner or operator of a source capable of emitting condensable particulate matter to include an analysis of the back half of the stack sampling train catch in the total particulate catch for any emission test using Method 5, 5A, 5B, 5D, 5E, 5F, 5G, 5H, 5I, or 17, in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13). This procedure and analysis shall be performed using Method 202 in 40 CFR part 51, Appendix M, incorporated by reference under s. NR 484.04 (9).
NR 439.07(8)(c)(c) Sulfur dioxide emissions.
NR 439.07(8)(c)1.1. When compliance with a sulfur dioxide emission limitation is determined using Method 6 or 6A in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), the test shall consist of 3 repetitions. A repetition shall consist of 2 20-minute sampling periods with each sampling period followed by a 15-minute fresh air purge. The 2 samples shall be analyzed independently. The arithmetic mean of the results of the 2 samples shall be the result of that repetition.
NR 439.07(8)(c)2.2. When compliance with a sulfur dioxide emission limitation is determined using Method 6B in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), the test shall consist of 3 24-hour repetitions with the sampling train operating continuously during each 24-hour repetition.
NR 439.07(8)(c)3.3. When compliance with a sulfur dioxide emission limitation is determined using Method 6C in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), the test shall consist of 3 representative repetitions.
NR 439.07(8)(d)(d) Nitrogen oxide emissions.
NR 439.07(8)(d)1.1. When compliance with a nitrogen oxide emission limitation is determined using Method 7, 7A or 7B in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), the test shall consist of 3 repetitions. A repetition shall consist of 4 2-liter evacuated sample bottles that are filled, one at a time, with stack gas at 15 minute intervals. The 4 samples shall be analyzed independently. The arithmetic mean of the results of the 4 samples shall be the result of that repetition.
NR 439.07(8)(d)2.2. When compliance with a nitrogen oxide emission limitation is determined using Method 7C, 7D, or 7E in 40 CFR part 60, Appendix A, incorporated by reference in s. NR 484.04 (13), the test shall consist of 3 representative repetitions.
NR 439.07(8)(e)(e) Organic compound emissions. When compliance with an organic compound emission limitation is determined using Methods 18, 25, 25A, 25B, or 320 in 40 CFR part 60, Appendix A, incorporated by reference under s. NR 484.04 (13), or ASTM D6348-12 (2020), incorporated by reference under s. NR 484.10 (55r), the test shall consist of a minimum of 3 representative repetitions.
NR 439.07(8)(f)(f) Visible emissions. When compliance with a visible emission limitation is determined using Method 9 in 40 CFR part 60, Appendix A-4, incorporated by reference in s. NR 484.04 (13), the test shall be performed based on the either of the following time criteria, unless otherwise specified in any applicable regulation, permit or compliance order:
NR 439.07(8)(f)1.1. For a new construction permit, operation permit or a renewal of an operation permit, the minimum total time of observations shall be 60 minutes, consisting of 10 6-minute averages.
NR 439.07(8)(f)2.2. For any other circumstances, the minimum total time of observations shall be 18 minutes, consisting of 3 6-minute averages.
NR 439.07(8)(g)(g) Exceptions. With department approval, compliance with pars. (a) to (e) may be determined as the arithmetic mean of 2 representative repetitions if 3 repetitions cannot be used to determine compliance because of any of the following circumstances:
NR 439.07(8)(g)1.1. A shutdown of the process being tested due to circumstances beyond the control of the source owner or operator.
NR 439.07(8)(g)2.2. A production cycle that does not allow for 3 repetitions of the test method.
NR 439.07(8)(g)3.3. The interruption of the test by unfavorable weather.
NR 439.07(8)(g)4.4. The accidental loss of a sample.
NR 439.07(8)(g)5.5. Any other circumstances beyond the control of the tester or the owner or operator of the source.
NR 439.07(9)(9)Emission test reporting requirements. For compliance emission tests, including initial certification tests and relative accuracy tests performed under s. NR 439.09, the owner, operator, or designee of the source tested shall submit to the department an emission test report within 60 calendar days after completion of a compliance emission test. If requested, the department may grant an extension of up to 30 calendar days for test report submittal. The failure to include any information required under this subsection in an emission test report may result in rejection of the test report submittal. The emission test report shall include all of the following information for the emissions unit tested:
NR 439.07(9)(a)(a) A detailed description of each emissions unit and control device.
NR 439.07(9)(am)(am) A detailed description of the reference test methods, analytical test methods, and quality control and quality assurance procedures used during the test.
NR 439.07(9)(ap)(ap) A description of any reference method or analytical test method deviation and a copy of any reference method or analytical test method deviation approval.
NR 439.07(9)(as)(as) The date, start and end times, duration, and number of sampling runs for each reference method and analytical test method.
NR 439.07(9)(b)(b) The operating conditions and parameters recorded at each emissions unit, including fuel type and sootblowing, and any associated air pollution control device during the test.
NR 439.07(9)(c)(c) A summary of test results expressed in units consistent with emission limitations applicable to the source.
NR 439.07(9)(d)(d) Sample calculations showing all the formulas used to calculate the reference test method and analytical test method results.
NR 439.07(9)(e)(e) The raw field and laboratory data for each repetition of each test.
NR 439.07(9)(f)(f) Calibration data for each reference method and analytical test method used during the test.
NR 439.07(9)(g)(g) The results of any quality assurance audit sample analyses required in each reference method or analytical test method.
NR 439.07(9)(h)(h) The results of any visible emission evaluations performed by the tester or source owner or operator and a copy of the visible emission certificate.
NR 439.07(9)(i)(i) A copy of any steam, opacity, or airflow charts made during the test.
NR 439.07(9)(j)(j) The report of any fuel analysis performed on the fuel burned during the test.
NR 439.07(9)(k)(k) Documentation of any emissions unit or control device upset conditions occurring during the test.
NR 439.07(9)(L)(L) An explanation of any excessive variation in the results when comparing the repetitions of the compliance emission test.